May 15, 2019

Buy ASTM D TEST METHOD FOR THERMAL-OXIDATIVE STABILITY OF POLYPROPYLENE USING A SPECIMEN ROTATOR. Find the most up-to-date version of ASTM D at Engineering ASTM D + REDLINE: STANDARD TEST METHOD FOR THERMAL- OXIDATIVE STABILITY OF POLYPROPYLENE USING A SPECIMEN ROTATOR .

Author: Moogut Goltill
Country: Benin
Language: English (Spanish)
Genre: Art
Published (Last): 3 August 2010
Pages: 159
PDF File Size: 4.66 Mb
ePub File Size: 10.16 Mb
ISBN: 984-7-58665-759-4
Downloads: 1062
Price: Free* [*Free Regsitration Required]
Uploader: Samujin

Send us a request Wilton UK: Here are the instructions on how to enable JavaScript in your web browser. Send us a request Need help or have a question? The method was originally developed for polypropylene but other plastics can be tested. If desired, lower temperatures can be applied to estimate the performance of polypropylene with lower heat stabilities. Historical Version s – view previous versions of standard Work Item s – proposed revisions of this standard Translated Version s: Work Item s – proposed revisions of this standard.

It is the responsibility astj the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

This test evaluates the heat aging characteristics of plastic specimens.

Evaluating how your products and services meet and exceed quality, safety, sustainability and performance standards. The test specimens are mounted in the clips on the biaxial rotator – spacers, such as teflon tape, are used to thermally insulate the specimens from the clips.

The category – similar standards: This website uses cookie files. Global Reach Intertek is the industry leader with over 42, people in 1, locations in over countries. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Need help or have a question? It is possible that some feature will not work.

Related Articles  GEDE NIBO PDF

Thermal-Oxidative Stability ASTM D, GMP

Note 2 — This test method and ISO — are technically similar but different in preparation of test specimens, thickness of test specimen, measurement of the number of air flow changes in d301 ovens, and the number of air changes per hour required. PDF – Immediate download – A bi-axial rotator and an air recirculation oven ensure uniform exposure to all specimens. The information about the standard: Auditing Consulting Sourcing Training. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

ASTM D3012

If desired, lower temperatures can astk applied to estimate the performance of polypropylene with lower heat stabilities. Formally confirming that your products and services meet all trusted external and internal standards. We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.

Your browser does not currently support JavaScript.

By browsing this website you expresses your consent with using cookies. Inspection Validating the specifications, value and safety of your raw materials, products and assets. Note 1 — The specified thermal levels in this test method are considered sufficiently severe to cause failure of commercial grades of heat-stable polypropylene within a reasonable period of time.

Look at this page. Technical standards updating Do you want to make sure you use only the valid technical standards?

ASTM – 10mm x 50mm x 1mm molded to size or cut from a larger piece. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. If desired, lower temperatures can be applied to estimate the performance of polypropylene materials with lower heat stability.

Link to Active This link will always route to the current Active version of the standard. GM – The test specimen is machined to no more than 75mm x 25mm x 3.

Related Articles  CARRIER 48TJE012 PDF

Standard ASTM D

Thermal degradation is determined by visual examination. Through our network of over 43, people in 1, laboratories and offices in countries, Intertek provides quality and safety solutions to a wide range of industries around the world. Enabling you to identify and mitigate the intrinsic risk in your operations, supply chains and business processes. Would you like to know more? The test can either be run for a specified period and then evaluated, or the samples can be evaluated at set periods to yield a time to failure.

Active view current version of standard. Certification Formally confirming that your products and services meet all trusted external and internal standards. If this test method is conducted at different temperatures on the same material, a more reliable estimate of the life-temperature relationship of polypropylene is determined.

If desired, lower temperatures can be applied to estimate the performance of polypropylene materials with lower heat stability. This test method can be conducted at several temperatures and the data interpreted through use of the Arrhenius relation, by plotting the logarithms of times to failure against the reciprocals of the temperatures in kelvins K.

Standards can be obtained from appropriate standards authorities. Whether your business is local or global, we can ensure your products meet quality, health, environmental, safety, and social accountability standards for virtually any market around the world. Assurance Enabling you to identify and mitigate the intrinsic risk in your operations, supply chains and business processes.

Work Item s – proposed revisions of this standard.

The values in parentheses are for information only.